Tyan Thunder CX TN200B7108-X4L (B7108T200X4-220PV3HR) - Downloads

(Item pictured represents B7108T200X4-220PV3HR only.)

 

How to Flash?

TYAN makes no warranties to the usability of a BIOS on our website and are made available to the public on an "as-is" basis. Upgrading a BIOS without knowing the implications may cause serious adverse affects. Please do not upgrade a BIOS unless directed to do so by a qualified support technician. TYAN is not able to replace mis-used or damaged BIOS chips in the event of a BIOS flash failure. Please contact your dealer for replacements or warranty service.

File Name:
TN200-B7108-X4L_v102 (12.9M)
File Date:
2018 / 07 / 26
Version:
V1.02.B20

Description:
- 1. Modify SPS SMLINK0 IPMB address to 0x20.
2. Modify HSC event SPS setting to disable.
3. Update Intel CPU uCode patch for Meltdown and Spectre.
M9750653_01000144 Intel(R) SkyLake Processor B-1 Stepping
MB750654_0200004D Intel(R) SkyLake Processor H-0, M-0, U-0 Stepping
4. Added health sensors states for Intel DCM function.
5. Added RAS-Report warning message and SEL while CPU be changed.
6. Added RAS-Report warning message and SEL while DIMM be changed.
7. Added Tyan smbios linux application support.
File Name:
TN200-B7108-X4L_v101 (12.9M)
File Date:
2018 / 05 / 16
Version:
V1.01.B20

Description:

1. Added report 64G DIMM information to BMC function.
2. Added report OCP-A slot information to BMC function.
3. Added set fan floor duty in BIOS setup menu.
4. Added when Intel VMD disable then HDD led function change to BMC.
5. Fixed when unplugging PSU the SDR status is incorrect issue.
File Name:
TN200-B7108-X4L_v100 (12.6M)
File Date:
2018 / 02 / 27
Version:
V1.00.B20

Description:

- TN200-B7108-X4L BIOS initialized.

 

File Name:
TN200-B7108_MCU_BMC_v300 (23.9M)
File Date:
2018 / 07 / 16
Version:
v3.00

Description:
-- Force ME Recovery before flash BIOS.
-- Fixed Set IP return error code.
-- Modify P12V sensor threshold to +-10%.
-- Fixed sensors which related to second CPU will not be disabled if second CPU is not present.
-- Fixed SYS_Air_Inlet, SYS_FAN_x event during AC cycle test.
-- Fixed a bunch of SEL errors relating to sensors going high during BMC warm reset.
-- Modify Event Page to fix time zone issue.
-- Change MB_Air_Outlet to SYS_Air_Outlet. -- OCP LAN Temperature support standard OCP Temperature sensor.
-- Modify fan curve.
-- Change PSU1/2 to PSU0/1.
-- Modify threshold for Voltage sensor according to EE's modification.
-- Push UID Button 5 second then trigger power button event (short press)
-- Add component change sensor.

NOTE: This BMC Firmware version v3.0 requires Chassis MCU firmware v1.01 . When updating to this MCU firmware version, ensure that the BMC firmware of every B7108 server node in the chassis is updated to ensure proper system operation.
File Name:
TN200-B7108_BMC_v200 (24M)
File Date:
2018 / 04 / 25
Version:
v2.00

Description:
-- FIX: Can't find 64G DIMM information on BMC UI.
-- FIX: Power LED will be abnormal when the setting of PCH After AC restore is last state & S0, and there is no CPU installed.
-- Support OCP slot information on WebUI.
-- Support Set fan floor duty in BIOS setup menu.
-- Change Power LED & IPMI Warnning LED behaivor according to PMM requirement.
-- Add OCP_LAN_Temp and modify fan control table.
File Name:
TN200-B7108_BMC_v100 (24M)
File Date:
2018 / 03 / 08
Version:
v1.00

Description:

-- TN200-B7108 BMC FW initialized.

Click the links below for the appropriate drivers and setup information. For .zip files, you must have a file compression / decompression utility such as WinZip. For .exe files, be sure to select the "Save" option when clicking on the file being downloaded, and choose your preferred drive location where you want the file to be saved.


Memory:
Memory Frequency:   
Vendor   Size   Voltage   Description(RoHS)
Vendor Part #   
Memory Chip /
Chip Part # /AMB Chip   
Datasheets:
Date   Filename   Version   
2017 / 11 / 15    DataSheet_TN200-B7108    v1.0   
HDD:
HDD/SSD Type:   
Vendor   Model   Form Factor   Interface   Capacity   
Click the links below to download utilities and setup information. For .zip files, you must have a file compression / decompression utility such as WinZip. For .exe files, be sure to select the "Save" option when clicking on the file being downloaded, and choose your preferred drive location where you want the file to be saved.


File Name:
TYAN_SMBIOS_V1.0 (61K)
File Date:
2018 / 07 / 23
Version:
V1.0
The DMI tool is designed for Tyan platforms only. It supports data re-written under 64bit Linux environment.


File Name:
7108_MCU_V101 (962K)
File Date:
2018 / 06 / 11
Version:
V1.01

Description:
Add a PSU PWRGD status command for BMC.

NOTE: This Chassis MCU firmware v1.01 requires BMC Firmware version v3.0. When updating to this MCU firmware version, ensure that the BMC firmware of every B7108 server node in the chassis is updated to ensure proper system operation.